3750 kVA Data Center Pad-Mounted Transformer
This 3750 kVA, 34.5/0.48 kV three-phase pad-mounted transformer is positioned for data center campuses and other critical-load facilities that receive medium-voltage service and distribute power at 480 V. It provides a project-specific interface between the site’s medium-voltage distribution system and downstream low-voltage equipment.
Data Center Power-Distribution Application
Data center transformer selection must be coordinated with the utility service, medium-voltage
switchgear, generators, transfer equipment, low-voltage switchboards and the facility’s redundancy strategy. A correct design considers more than rated kVA: impedance, available fault current, voltage regulation, energization, protection coordination, cable arrangement and future expansion can all affect the final configuration.
Known Project Rating
Rated capacity: 3750 kVA
Primary voltage: 34.5 kV
Secondary voltage: 0.48 kV (480 V)
Phase: Three phase
Installation: Pad-mounted
Application focus: Data center and mission-critical power distribution
Configuration Confirmed During Engineering Review
Because data center electrical architectures vary, the final winding connection, impedance, taps, winding material, feed arrangement, insulating liquid, protective devices, accessories, enclosure details and interface dimensions are not assumed from a generic configuration. Qinghe Electric reviews the customer’s one-line diagram, technical specification and site requirements before issuing final drawings and a project data sheet.
UL-Oriented Production Capability
The transformer is manufactured on Qinghe Electric’s UL-oriented production line for North American and international projects. Applicable listing, certification and marking requirements depend on the final engineered configuration and are confirmed during quotation and technical review.
Factory Inspection and Project Documentation
Manufacturing follows the approved drawings and project specification. Routine factory testing and technical documentation can be supplied according to the agreed scope. The product gallery shows the completed pad-mounted transformer, core-and-coil assembly and internal terminal compartments.
Information Needed for a Data Center Quotation
Please provide the one-line diagram, required quantity, redundancy arrangement, primary and secondary voltage, winding connection, frequency, impedance requirement, winding material, feed arrangement, insulating liquid, protective accessories, applicable standards, destination country and required on-site date.
For general ratings and construction options, visit our pad-mounted transformer overview.