1000 kVA Cast Resin Dry Type Transformer

Product Advantages


Capacity Matched to Substantial Building or Process Loads

The 1000 kVA rating suits projects that need a dedicated transformer for a defined load center rather than a broad product-range page.


Encapsulated Windings

Epoxy cast resin protects the windings from moisture and airborne contamination under the approved environmental design conditions.


Installation Options

Supply can be open type for a controlled transformer room or fitted with a project-specified protective enclosure.


Cooling Selected for the Duty

Air-natural cooling is the normal basis; forced-air equipment can be evaluated when the load profile and thermal design require it.


Documented Project Build

Voltage ratio, vector group, impedance, taps, conductor and accessories are confirmed on approved drawings before production.

Product Details

1000 kVA Cast Resin Dry Type Transformer


Product Introduction

The 1000 kVA cast resin dry type transformer is designed for indoor medium-voltage distribution where an oil-free installation, compact maintenance plan and project-specific electrical configuration are required. It can be engineered for commercial buildings, manufacturing facilities, data infrastructure and other sites that distribute power close to occupied or process areas.


Typical Applications

Typical uses include main or sub-main distribution in shopping centers, office complexes, factories, hospitals, data facilities and infrastructure buildings. The final selection must reflect room ventilation, altitude, ambient temperature, fire-safety rules and the required enclosure rating.


Typical Project Configuration

Rated Capacity: 1000 kVA

Construction: Three-phase epoxy cast-resin dry type

Primary / Secondary Voltage: Project specific

Frequency: 50 Hz or 60 Hz

Conductor: Copper or aluminum, as specified

Cooling: AN; AF when engineered

Enclosure: Open indoor type or specified protective enclosure

Standards: Applicable IEC, IEEE, UL or customer specification


Frequently Asked Questions

Can the voltage ratio be customized?

Yes. Primary and secondary voltage, taps and vector group are confirmed from the project single-line diagram and approved data sheet.


Is this page for VPI or cast resin construction?

This product page is for epoxy cast resin construction. VPI open-wound transformers should be quoted as a separate design when the application favors VPI.


What information is needed for pricing?

Provide voltage, frequency, vector group, impedance, conductor, enclosure/IP rating, altitude, ambient temperature, standards, accessories, quantity and destination.


Quotation Information

For a 1000 kVA quotation, send the primary and secondary voltage, frequency, vector group, impedance, tap range, copper or aluminum winding preference, enclosure/IP rating, room conditions, altitude, accessories, quantity and destination. Final values are confirmed on the approved data sheet and drawings.