SCB12 80 kVA Cast-Resin Dry-Type Transformer

Product Advantages

Purpose-Built for Small Load Groups

The 80 kVA rating can support auxiliary systems, workshops, small commercial services or dedicated equipment when validated by the load calculation.


Compact Project Integration

The final footprint, cable entry and enclosure can be coordinated with limited installation space.


Oil-Free Cast Resin Construction

Epoxy-encapsulated windings avoid the liquid containment requirements associated with oil-filled equipment and support indoor installation under approved environmental conditions.


Air-Natural Cooling

AN cooling is normally suitable for this capacity, subject to the approved thermal design and transformer-room ventilation.


Configurable Electrical Interface

Voltage ratio, taps, vector group, conductor material and accessories are selected to match the connected system and approved project documents.

Product Details

SCB12 80 kVA Cast Resin Dry Type Transformer


Product Introduction

The SCB12 80 kVA cast resin dry type transformer provides a compact oil-free option for localized three-phase loads and auxiliary distribution. It is suited to projects where the transformer serves a clearly defined small load group and must fit within an indoor electrical room, equipment area or protective enclosure.


Typical Applications

Typical applications include auxiliary building services, control and maintenance areas, small workshops, localized commercial loads and dedicated equipment supplies. Capacity should be confirmed from continuous demand, motor starting current, harmonic content and future expansion allowance.


Typical Project Configuration

Model: SCB12

Rated Capacity: 80 kVA

Phase: Three phase

Insulation: Epoxy cast resin

Primary and Secondary Voltage: Project specific

Frequency: 50 Hz or 60 Hz

Winding Material: Copper or aluminum, as specified

Cooling: AN; other arrangements subject to engineering review

Installation: Indoor or project-specified protective enclosure

Applicable Standards: IEC, IEEE or customer specification, as applicable

Testing: Applicable routine factory tests with test report


Frequently Asked Questions

Is 80 kVA enough for my load?

Confirm the diversified load, motor starting demand, harmonics and future growth. Nameplate capacity should not be selected from connected load alone.


Can it be supplied with copper windings?

Yes. Copper or aluminum can be specified and will be stated in the approved technical documents.


Can this transformer be installed outdoors?

Outdoor use requires a suitable enclosure and environmental design. Provide the required IP rating, temperature, altitude and site-exposure details.


Quotation Information

To price the 80 kVA cast resin unit, confirm the actual load group, primary and secondary voltage, phase, frequency, vector group, impedance, winding material, enclosure, installation environment, quantity and delivery destination.

Leave your messages

Related Products