SCB12 50 kVA Cast-Resin Dry-Type Transformer

Product Advantages

• Oil-Free Dry-Type Design: Suitable for indoor power distribution where fire safety, cleanliness and reduced maintenance are important.

• Epoxy Cast-Resin Construction: The SCB12 design uses encapsulated windings for moisture resistance, mechanical strength and reliable service.

• Project Flexibility: Primary and secondary voltage, winding material, enclosure, taps, impedance and accessories are engineered to the approved project specification.

• Cooling Options: Air-natural (AN) cooling is standard for applicable designs; forced-air (AF) cooling can be engineered when required.

• Factory Testing: Routine factory tests and a test report are provided according to the applicable project requirements.

Product Details

SCB12 50 kVA Cast-Resin Dry-Type Transformer

This page covers an SCB12 three-phase epoxy cast-resin dry-type transformer with a rated capacity of 50 kVA. It is intended for safe and reliable indoor power distribution in commercial, industrial and infrastructure projects.

Typical Project Configuration

Model: SCB12

Rated Capacity: 50 kVA

Product Type: Three-phase epoxy cast-resin dry-type transformer

Primary and Secondary Voltage: Project-specific; confirmed in the approved drawings and data sheet

Frequency: 50 Hz or 60 Hz, as specified

Winding Material: Copper or aluminum, as specified

Cooling: AN; AF available when engineered for the project

Insulation and Temperature Rise: Confirmed according to the approved design and project requirements

Enclosure: Indoor open construction or project-specified enclosure

Applicable Standards: Applicable IEC, IEEE or customer specifications, as agreed for the project

Testing: Routine factory tests with test report

VPI and Cast-Resin Dry-Type Transformer Capability

This SCB12 product is an epoxy cast-resin design. Jinan Qinghe Electric can also manufacture vacuum-pressure-impregnated (VPI) open-wound dry-type transformers for suitable applications. The final construction—VPI or epoxy cast resin—is selected according to the installation environment, voltage class, enclosure, applicable standards and approved project specification.

Information Required for Quotation

Please provide the rated capacity, primary and secondary voltage, phase, frequency, winding material, enclosure, quantity, required standards, destination country and delivery schedule. Final technical values are confirmed in the approved drawings and data sheet before production.

Leave your messages